英文取説納付時の注意事項
本書に含まれる以下の要素は、案件毎に修正が必要となる可能性があります。
納付時には対象製品の仕様を確認の上、必要に応じて修正を加えてください。
1) P.7 "10. Choose a correct power distribution board or receptacle"中、電源仕様に関する表記。
Electric capacity:
IQ820: 100V AC, 20A
2) P.38 "Specification"中、電源仕様に関する表記。
3) P.40 "Wiring Diagram"の結線図中、入力電源表記。
4) P.41 "Replacement Parts Table"中、各種交換部品の電圧・電気容量に関する表記。
以上
Page view 0
1 2 3 4 5 6 ... 45 46

Summary of Contents

Page 1 - 英文取説納付時の注意事項

英文取説納付時の注意事項 本書に含まれる以下の要素は、案件毎に修正が必要となる可能性があります。 納付時には対象製品の仕様を確認の上、必要に応じて修正を加えてください。 1) P.7 "10. Choose a correct power distribution board or

Page 2 - - First Edition

7 Before Using this unit Requirements for Installation CAUTION! 10. Choose a correct power distribution board or receptacle • Choose a correct po

Page 3 - Contents

8 Before Using this unit Defrost in Refrigerator Much frost on the evaporator degrades the refrigeration capability, which may cause uncontrollabil

Page 4

9 Description and Function of Each Part Main Unit Rear view Front view Lock unit (Upper) Defrost control panel Drain hoses (for upper and l

Page 5 - Table of Illustrated Symbols

10 Description and Function of Each Part Control Panel No. Name Function ① START/STOP Key: Starts/stops the operation. ② ▲▼ Key: Uses for

Page 6

11 Description and Function of Each Part Defrost Control Panel MANUAL DEFROST ON CYCLE DEFROST ON OFF UPPER MANUAL DEFROST ON CYCLE DEFROST ON OFF

Page 7

12 Description and Function of Each Part Characters of the Controller The characters VS4 controller shows are as follows: Character Identifier Na

Page 8

13 Operation Method Operation Mode and Function List All the operation mode of this unit is as follows; No. Name Description Page 1. Fixed Tempe

Page 9

14 Operation Method Operation Mode and Function List The operation function of this unit is as follows; No. Name Description Page Auto overheati

Page 10 - CAUTION!

15 Operation Method Operation Mode, Function Setting Key, and Characters The operation mode setting and function setting use the key operation and

Page 11

16 Operation Method Setting of Overheating Prevention Device The unit has the overheating prevention device (manual reset) that consists of indepen

Page 12 - Main Unit

Programmable Low Temperature Incubator Model IQ820 Instruction Manual - First Edition - Yamato Scientific Co. LTD. l Thank you for purchasing &qu

Page 13 - Control Panel

17 Operation Method Fixed Temperature Operation Fixed temperature operation procedure 1. Turn on the power (turn on the breaker in front) v Current

Page 14 - Defrost Control Panel

18 Operation Method Quick Auto Stop Operation Quick auto stop operation procedure This operation is used to specify the period up to automatic

Page 15 - Characters of the Controller

19 Operation Method Auto Stop Operation Auto stop operation procedure This operation is used to specify the automatic stop time in the fixed te

Page 16 - Operation Method

20 Operation Method Auto Stop Operation 3. Stop/terminate timer operation • The operation stops automatically at setting time. • Buzzer continu

Page 17

21 Operation Method Auto Start Operation Auto start operation procedure This operation is used to specify the period up to automatic start afte

Page 18

22 Operation Method Auto Start Operation 3. Stop/terminate timer operation • The operation starts automatically at setting time. • Press the ST

Page 19

23 Operation Method Program Operation This operation is used to change the temperature according to the setting temperature and time. Progr

Page 20

24 Operation Method Program Operation Program creation POWER 1. Turn on the power • Turn on the power switch of the unit. • The display on t

Page 21

25 Operation Method Program Operation The example shown below explains the method of program registration using "PrG3". 3. Register pro

Page 22

26 Operation Method Program Operation 4. Start program operation • Press the START/STOP key for about one second. The program operation previou

Page 23

Contents u Cautions in Using with Safety...1 • Explanation ...

Page 24

27 Operation Method Program Operation Use program repeat function This section explains how to register the program repeat (repeating a program patt

Page 25

28 Operation Method Program Operation Programming Preparation Form 1 (Please use this form by making copies) Register with: PrG1 PrG2 PrG3 PAt

Page 26

29 Operation Method Program Operation Programming Preparation Form 2 (Please use this form by making copies) Register with: PrG1 PrG2 PrG3 PAt

Page 27

30 Operation Method Other Functions Use calibration offset function Calibration offset is a function which corrects the difference between the tempe

Page 28

31 Handling Precautions WARNING! If a problem occurs If smoke or strange odor should come out of this unit for some reason, turn off the power ke

Page 29

32 Handling Precautions Setting of sample Since the withstand load of the attached shelf plate is about 15kg per one plate, do not set heavier

Page 30

33 Maintenance Method Daily Inspection and Maintenance For the safety use of this unit, please perform the daily inspection and maintenance without

Page 31

34 Long storage and disposal When not using this unit for long term / When disposing CAUTION! When not using this unit for long term… • Turn off t

Page 32

35 In the Event of Failure… Safety Device and Error Code This unit has an automatic diagnosis function built in the controller and safety devices i

Page 33 - ℃ to plus side and

36 In the Event of Failure… Trouble Shooting Problem Possible Cause Solution Earth leakage breaker failure Replace the part. Power switch fail

Page 34 - WARNING!

1 Cautions in Using with Safety Explanation MEANING OF ILLUSTRATED SYMBOLSVarious symbols are used in this safety manual in order to use the unit

Page 35

37 After Service and Warranty In Case of Request for Repair If the failure occurs, stop the operation, turn OFF the power switch, and unplug the

Page 36 - Maintenance Method

38 Specification Model IQ820 Method Forced circulation Temperature control range -10 to 50℃ (Common to upper/lower unit) Temperature adjustme

Page 37 - Long storage and disposal

39 Specification External dimensions 710W×645D×1630H mm Internal dimensions 600W×477D×500H mm × 2 Capacity 143L × 2 Withstand load of shelf

Page 38 - In the Event of Failure…

40 Wiring Diagram 1SSR1P1ELBH1FM2FM1X3X1 X2-12345876CT1AC100V①②③④⑤②②①⑧CONT1123CN512CN4CN23221CN114365H2118CN2PIO1118TB1 21CN9TH1118CN8CN11183109MV2

Page 39

41 Replacement Parts Table Symbol Part Name Specification Manufacturer Code No. X1, 2, 3, 6, 7, 8 Relay AP3124K Matsushita A0334 X4, 5 R

Page 40 - After Service and Warranty

42 Reference List of Dangerous Substances Never use explosive substances, flammable substances and substances that include explosive or flammable

Page 41 - Specification

43 Responsibility Please follow the instructions in this document when using this unit. Yamato Scientific has no responsibility for the accidents o

Page 42

2 Cautions in Using with Safety Table of Illustrated Symbols Warning Warning, generally Warning, high voltage Warning, high temperature Warn

Page 43 - Wiring Diagram

3 Cautions in Using with Safety Fundamental Matters of "WARNING!" and "CAUTION!" WARNING! Do not use this unit in an area wh

Page 44 - Replacement Parts Table

4 Before Using this unit Requirements for Installation WARNING! 1. Always ground this unit • Be sure to connect the earth wire (the green cable o

Page 45 - Reference

5 Before Using this unit Requirements for Installation 5. Do not use this unit in an area where there is flammable or explosive gas (Refer to page

Page 46 - Yamato Scientific Co., Ltd

6 Before Using this unit Requirements for Installation 6. Do not modify 7. Installation on horizontal surface • Modification of this unit is str

Comments to this Manuals