Low Temperature Incubator
Model
IJ 201/300/300W
Instruction Manual
- Second Edition -
Yamato Scientific Co. LTD.
z Thank you for purchasing "Low Temperature
Incubator, IJ Series" of Yamato Scientific Co.,
Ltd.
z To use this unit properly, read this "Instruction
Manual" thoroughly before using this unit.
Keep this instruction manual around this unit for
referring at anytime.
WARNING!:
Carefully read and thoroughly understand the
important warning items described in this manual
before using this unit.
Page view 0
1 2 3 4 5 6 ... 49 50

Summary of Contents

Page 1 - IJ 201/300/300W

Low Temperature Incubator Model IJ 201/300/300W Instruction Manual - Second Edition - Yamato Scientific Co. LTD. z Thank you for purchasing "

Page 2

6 Before Using this unit Requirements for Installation CAUTION! 6. Do not make an overload 7. Do not set samples in close formation • The withs

Page 3 - Contents

7 Before Using this unit Requirements for Installation 11. Drain of dew drops • Use the attached tray for drain of dew drops. They may occur i

Page 4

8 Before Using this unit Change the Direction of Opening/Closing Door (only for IJ300/300W)  IJ300/300W can be changed the direction of opening/c

Page 5

9 Description and Function of Each Part Main Unit IJ201 YyamatoIJ201 Door handle Front view Rear view Power switch (Earth leakage bre

Page 6 - Table of Illustrated Symbols

10 Description and Function of Each Part Main Unit IJ300/300W Low tem p incubatorIJ300 Door packing Front view Rear view Power switch (Eart

Page 7

11 Description and Function of Each Part Control Panel POWER ① START/STOP Key: Starts/stops the operation. ② ▲▼ Key: Uses for rising UP/loweri

Page 8

12 Description and Function of Each Part Characters of the Controller The characters VS4 controller shows are as follows: Character Identifier Nam

Page 9

13 Operation Method Operation Mode and Function List All the operation mode of this unit is as follows; No. Name Description Page1. Fixed Tempera

Page 10 - CAUTION!

14 Operation Method Operation Mode and Function List The operation function of this unit is as follows; No. Name Description PageAuto overheating

Page 11

15 Operation Method Operation Mode, Function Setting Key, and Characters The operation mode setting and function setting use the key operation and

Page 13 - Main Unit

16 Operation Method Setting of Overheating Prevention Device The unit has the overheating prevention device (manual reset) that consists of indepen

Page 14

17 Operation Method Fixed Temperature Operation Fixed temperature operation procedure 1. Turn on the power (turn on the breaker in front)  The def

Page 15 - Control Panel

18 Operation Method Quick Auto Stop Operation Quick auto stop operation procedure This operation is used to specify the period up to automatic

Page 16 - Characters of the Controller

19 Operation Method Auto Stop Operation Auto stop operation procedure This operation is used to specify the automatic stop time in the fixed te

Page 17 - Operation Method

20 Operation Method Auto Stop Operation 3. Stop/terminate timer operation • The operation stops automatically at setting time. • Buzzer continu

Page 18

21 Operation Method Auto Start Operation Auto start operation procedure This operation is used to specify the period up to automatic start afte

Page 19

22 Operation Method Auto Start Operation 3. Stop/terminate timer operation • The operation starts automatically at setting time. • Press the ST

Page 20

23 Operation Method Program Operation This operation is used to change the temperature according to the setting temperature and time. Progr

Page 21

24 Operation Method Program Operation Program creation The program pattern below is explained as an example. 1. Program pattern example Temp.

Page 22

25 Operation Method Program Operation The example shown below explains the method of program registration using PrG3. 4. Register program ① Sele

Page 23

Contents  Cautions in Using with Safety...1 • Explanation...

Page 24

26 Operation Method Program Operation 5. Start program operation • Press the START/STOP key for about one second. The program operation previou

Page 25

27 Operation Method Program Operation Use program repeat function This section explains how to register the program repeat (repeating a program patt

Page 26

28 Operation Method Program Operation Programming Preparation Form 1 (Please use this form by making copies) Register with: PrG1 PrG2 PrG3 PA

Page 27

29 Operation Method Program Operation Programming Preparation Form 2 (Please use this form by making copies) Register with: PrG1 PrG2 PrG3 PA

Page 28

30 Operation Method Other Functions Use calibration offset function Calibration offset is a function which corrects the difference between the tempe

Page 29

31 Operation Method Other Functions Use Shaker Small shaker(s), such as shaker MK140 type, can be installed in IJ300W type. the cable for taking out

Page 30

32 Handling Precautions WARNING! If a problem occurs If smoke or strange odor should come out of this unit for some reason, turn off the power ke

Page 31

33 Handling Precautions Do not use corrosive sample Stainless steel SUS304 is used for interior; however, it may be corroded by strong acid etc.

Page 32

34 Maintenance Method Daily Inspection and Maintenance For the safety use of this unit, please perform the daily inspection and maintenance without

Page 33

35 Maintenance Method Daily Inspection and Maintenance Cleaning of radiating fin Unplug the power plug at cleaning • Clogging on the fin degrades

Page 35

36 Setting of Air Jacket (Optional accessory) 1. Set the shelf at the lowest stage in a way that the side with margin may come innermost. 2. Set

Page 36 - Handling Precautions

37 Long storage and disposal When not using this unit for long term / When disposing CAUTION! When not using this unit for long term… • Turn off t

Page 37

38 In the Event of Failure… Safety Device and Error Code This unit has an automatic diagnosis function built in the controller and safety devices i

Page 38 - Maintenance Method

39 In the Event of Failure… Trouble Shooting Before call us... Condition Possible Causes The device does not start when turning on the power swi

Page 39

40 After Service and Warranty In Case of Request for Repair If the failure occurs, stop the operation, turn OFF the power switch, and unplug the

Page 40

41 Specification Model IJ201 IJ300 IJ300W Temperature control range 0 to 60℃ (Ambient temp.: 20℃, No load) Temperature adjustment accuracy ±

Page 41 - Long storage and disposal

42 Wiring Diagram IJ201 1X11234P13421CTX13SSR123421CN5CN4CN8CN1118118CN2CN112PIOCONTELBAC100V256CN9CN211811831TB22+-HTH213TB12ATH1BbX212F2F1C2C11

Page 42 - In the Event of Failure…

43 Wiring Diagram IJ300/300W 1X11234P13421CTX13SSR123421CN5CN4CN8CN1118118CN2CN112PIOCONTELBAC100V256CN9CN211811831TB22+-HTH213TB12ATH1BbX212F2F1

Page 43

44 Replacement Parts Table IJ201 Part Name Specification Manufacturer Code No. W sensor NL-201RB-J0001 Pt100/K Yamato Scientific 1160030053

Page 44 - After Service and Warranty

45 Reference List of Dangerous Substances Never use explosive substances, flammable substances and substances that include explosive or flammable

Page 45 - Specification

1 Cautions in Using with Safety Explanation MEANING OF ILLUSTRATED SYMBOLSVarious symbols are used in this safety manual in order to use the unit

Page 46 - Wiring Diagram

46 Responsibility Please follow the instructions in this document when using this unit. Yamato Scientific has no responsibility for the accidents o

Page 47

2 Cautions in Using with Safety Table of Illustrated Symbols Warning Warning, generally Warning, high voltage Warning, high temperatureWarnin

Page 48 - Replacement Parts Table

3 Cautions in Using with Safety Fundamental Matters of "WARNING!" and "CAUTION!" WARNING! Do not use this unit in an area wh

Page 49 - Reference

4 Before Using this unit Requirements for Installation WARNING! 1. Always ground this unit • Be sure to connect the earth wire (the green cable

Page 50 - Yamato Scientific Co., Ltd

5 Before Using this unit Requirements for Installation 3. Do not use this unit in an area where there is flammable or explosive gas (Refer to page

Comments to this Manuals

No comments