Yamato-scientific DVS602 Constant Temperature Drying Oven User Manual

Browse online or download User Manual for Equipment Yamato-scientific DVS602 Constant Temperature Drying Oven. Yamato Scientific DVS602 Constant Temperature Drying Oven User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 47
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Constant Temperature
Drying Oven
Model DVS402
DVS602
First edition
Thank you very much for purchasing this Yamato
DVS series constant temperature drying oven.
Please read the “Operating Instructions” and
“Warranty” before operating this unit to assure
proper operation. After reading these documents,
be sure to store them securely together with the
“Warranty” at a handy place for future reference.
Warning! Before operating the unit, be sure to
read carefully and fully understand
important warnings in the operating
instructions.
Yamato Scientific Co., Ltd.
Page view 0
1 2 3 4 5 6 ... 46 47

Summary of Contents

Page 1 - Drying Oven

Constant Temperature Drying Oven Model DVS402 DVS602 First edition ● Thank you very much for purchasing this Yamato DVS series constant temp

Page 2 - Table of contents

8 2. Before operating the unit Precautions when installing the unit Caution 11. About handling of the power cord Never use electrical power c

Page 3 - 1. Safety precautions

9 3. Names and functions of parts Main body Front view Rear panel Control panel Door Handle Main switch (Earth leakage breaker) Ra

Page 4

10 3. Names and functions of parts Operation panel MEASURED TEMP. ℃HEATERALARMAUTO STOPAUTO STARTENTER SETTEMP.OVER TEMP.PROTECTORFIXED TEMP.RUN S

Page 5

11 3. Names and functions of parts Explanation of characters Characters on the VS4 type controller are explained in this section. Characters Ident

Page 6

12 3. Names and functions of parts Explanation of characters Characters Identifier Name Application cAL Calibration offset settingUsed for inp

Page 7

13 4. Operating procedures List of operation modes and functions Operation modes of the unit are as shown below: № Name Description Page1 Fixed tem

Page 8 - Alteration

14 4. Operating procedures List of operation modes and functions Operating functions of the unit are as shown below: № Name Description Page1 Overh

Page 9

15 4. Operating procedures Operation mode・function setting keys and characters Key operations and characters in the diagram below are used for operat

Page 10 - 2. Before operating the unit

16 4. Operating procedures Settings for overheat prevention device The safety device for preventing overheat has the automatic overheat prevention fu

Page 11 - Main body

17 4. Operating procedures Operating procedures (fixed temperature operation) How to start fixed temperature operation MEASURED TEMP. ℃HEATERALARM

Page 12 - Operation panel

Table of contents 1. Safety precautions ...

Page 13 - Explanation of characters

18 4. Operating procedures Operating procedures (quick auto stop operation) Procedures for quick auto stop operation Used when you want to, for examp

Page 14

19 4. Operating procedures Operating procedures (auto stop operation) Procedures for auto stop operation Used when you want to “set automatic stop af

Page 15 - 4. Operating procedures

20 4. Operating procedures Operating procedures (auto stop operation) MEASURED TEMP. ℃ HEATERALARMAUTO STOPAUTO STARTENTER SETTEMP.OVER TEMP.PROTECT

Page 16

21 4. Operating procedures Operating procedures (auto start operation) Procedures for auto start operation Used when you want to “start operation aut

Page 17

22 4. Operating procedures Operating procedures (auto start operation) MEASURED TEMP. ℃ HEATERALARMAUTO STOPAUTO STARTENTER SETTEMP.OVER TEMP.PROTEC

Page 18

23 4. Operating procedures Preparing a program Program operation Used when you want to “operation at an increased or decreased temperature according

Page 19

24 4. Operating procedures Preparing a program Heating・cooling time of the DVS model Rough heating and cooling times of the DVS model are as follow

Page 20

25 4. Operating procedures Preparing a program MEASURED TEMP. ℃ HEATERALARMAUTO STOPAUTO STARTENTER SETTEMP.OVER TEMP.PROTECTORFIXED TEMP.RUN STOP S

Page 21

26 4. Operating procedures Preparing a program MEASURED TEMP. ℃ HEATERALARMAUTO STOPAUTO STARTENTER SETTEMP.OVER TEMP.PROTECTORFIXED TEMP.RUN STOP S

Page 22

27 4. Operating procedures Preparing a program MEASURED TEMP. ℃ HEATERALARMAUTO STOPAUTO STARTENTER SETTEMP.OVER TEMP.PROTECTORFIXED TEMP.RUN STOP S

Page 23

1 1. Safety precautions Explanation of pictograms A variety of pictograms are indicated in this operating instruction and on products to assure

Page 24

28 4. Operating procedures Program repeat operation Using the program repeat function This section explains how to register a program pattern to be r

Page 25

29 4. Operating procedures Programming sheet Make duplicates as necessary. Registration destination PrG1 PrG2 PrG3 PAt1 PAt2 PAt3 Control No.

Page 26

30 4. Operating procedures Programming sheet Make duplicates as necessary. Registration destination PrG1 PrG2 PrG3 PAt1 PAt2 PAt3 Control No.

Page 27

31 4. Operating procedures Useful functions (calibration offset function) Using the calibration offset function Calibration offset function compensat

Page 28

32 4. Operating procedures Useful function (lock function) Using the lock function MEASURED TEMP. ℃ HEATERALARMAUTO STOPAUTO STARTENTER SETTEMP.OVE

Page 29

33 5. Cautions on handling Warning 1. About substances that cannot be used for the unit Never use an explosive substance, a flammable substance or

Page 30

34 5.Cautions on handling Caution 7. About placement of samples Withstand load of the shelf boards included is approx. 15kg. Do not place a sample

Page 31

35 6. Maintenance procedures Daily inspection/maintenance Warning z Be sure to pull out the power cord for the power supply unless necessary befor

Page 32

36 7. When the unit is not to be used for a long time or when disposing When the unit is not to be used for a long time or when disposing Caution W

Page 33

37 8. Troubleshooting Safety device and error codes The unit has the self diagnostic function with a controller and a separate safety device. Table b

Page 34

2 1. Safety precautions List of symbols Warning General warnings Danger!: High voltage Danger!: High temperatureDanger!: Moving part Danger!:Haz

Page 35 - 5. Cautions on handling

38 8. Troubleshooting When a malfunction is suspected If any of the symptoms below occurs Symptom Check The unit is not activated even if the power

Page 36 - Placing a shelf board

39 9. After sales service and warranty When requesting a repair When requesting a repair If any trouble occurs, immediately stop operation, turn the

Page 37 - 6. Maintenance procedures

40 10. Specifications Model DVS402 DVS602 Operating temperature range Room temperature +5℃∼260℃(no load at an ambient temperature of 23℃) Temperat

Page 38 - Caution Warning

41 11. Wiring diagram DVS402/602 1234TELBAC100VHX3412CTX1SSR2113TB1CN2CN112CONT321TB22+-TH2TH1+-CN8CN1118118PIOCN9CN21181181234CN456...13CN52..

Page 39 - 8. Troubleshooting

42 12. List of replacement parts Common replacement parts for DVS402/602 Part name Standard Maker Code No. 1 Sensor LCK-M1-2000Y @K single Yamat

Page 40

43 13. List of dangerous materials Never use an explosive material, a flammable material or a material containing them for this device. ① Nitrogl

Page 41 - When requesting a repair

44 14. Standard installation manual *Install the product according to the following: (Confirm separately for optional items or special specifications

Page 42 - 10. Specifications

45 Limited liability Be sure to use the unit strictly following the handling and operating instructions in this operating instruction. Yamato Scientif

Page 43 - 11. Wiring diagram

3 1. Safety precautions Warning・Cautions Warning Never operate the unit in an atmosphere containing flammable or explosive gas Never operate the

Page 44

4 2. Before operating the unit Precautions when installing the unit Warning 1. Be sure to connect the ground wire. ・ Power supply for this product

Page 45 - Flammable substances

5 2. Before operating the unit Precautions when installing the unit Warning 3. Never operate the unit in an atmosphere containing explosive or flamm

Page 46

6 2. Before operating the unit Precautions when installing the unit Warning 4. Do not alter the product. 5. Install the unit on a level surface T

Page 47 - Limited liability

7 2. Before operating the unit Precautions when installing the unit Caution 8. Be sure to connect the power plug to the dedicated wall outlet. Use

Comments to this Manuals

No comments